ID persistente del dataset
|
doi:10.21950/MJFJM2 |
Fecha de publicación
|
2016-11-25 |
Título
| Experiment STAbility of liquid COlumns (STACO) on the Advanced Fluid Physics Module (FPM) aboard Spacelab-D2 |
Subtítulo
| liquid bridge under microgravity |
Título alternativo
| SL-D2-WL-AFPM-STACO |
Otra ID
| European Space Agency (ESA): 0000 0001 2163 0931
0000 0004 0623 6946 |
Autor
| Martínez Herranz, Isidoro (UPM) - ORCID: 0000-0003-0994-5898
Perales Perales, José Manuel (UPM) - ORCID: 0000-0001-9873-8115
Meseguer Ruiz, José (UPM)
Ulrich Walter (Technische Universität München) |
Contacto
|
Utilice el botón de e-mail de arriba para contactar.
Archivo Digital UPM (Universidad Politécnica de Madrid)
González González, Jose Ignacio (Universidad Politécnica de Madrid) |
Descripción
| During the second German Mission of Spacelab (1993, Spacelab D-2) an experiment on the mechanical stability of liquid columns was performed. A liquid column is a liquid mass held between to solid (circular) supports. A 30 mm in diameter and 90 mm long liquid drop was stablished in the Advanced Fluid Physics Module (AFPM) and was subjected to different mechanical stimuli (rotation of the supports, oscillation of one of the supports, change in volume and in length) to check whether the resulting drop was stable or not. Results were obtained in terms of images and recorded in a video sequence. Telemetry of the different stimuli and parameter values was also recorded. Objetive: The aim of this experiment was to measure the outer shape deformation of long liquid bridges near their stability limit under microgravity, caused by g-jitters and by some controlled mechanical disturbances (change of geometry, change of volume, rotation and vibration). The liquid used was a silicone-oil 10 times more viscous than water (5 times for the last run). The working length of the liquid column was 85 mm. The two solid supports are made of aluminium, of 30 mm in diameter, with a sharp cutback (30 deg. edge) to prevent liquid spreading over the edges. This choice of geometry allows a direct comparison with other TEXUS experiments where two discs of 30 mm in diameter and 86 mm apart were used to hold a cylindrical liquid column (35 mm discs were used in SL-D1 and 40 mm discs on SL-1). A top priority was to verify the results of a previous experiment performed on SL-D1, and because an equivalent Bond number Bo=0.007 was deduced from this experiment and there was no reason to expect a different behaviour, it was planned, in a second run to make use of unequal discs of 30 mm and 28 mm in a second run to precisely counterbalance the expected deformation and better quantify this effect. Procedures: The actual procedures executed were: -- Run 1: background sensing, disc oscillation at 0.40 Hz, 0.41 Hz, 0.42 Hz and again 0.42 Hz. -- Run 2: background sensing and disc separation until breakage of the column. -- Run 3: background sensing. Results: An example of free oscillations of a liquid column (diameter 30 mm, length 85 mm, volume 60 cc), due to g-jitter, is shown in Video1, recorded during the background sensing phase of Run 2. Video2 shows the breakage of the same column caused by disc separation at constant volume. This experiment enabled to accurately measure the response of the 85 mm-long cylindrical liquid column to a forced axial vibration of one of the supporting discs, and found that it is in very good agreement with theory, and complements other measurements performed in the same flight but with shorter columns by D. Langbein. An achievement is the high accuracy reached in automatic image analysis, of the order of 30 microns in object size (0.1 pixels in the 512*512 image), which represents a great improvement in comparison to the manually digitised hard-prints of previous flights. The more puzzling question left after the experiment is the lack of reproducibility of the steady averaged deformation measurement, perhaps because it is not a characteristic of the configuration and may be dependent on details of hardware (e.g. materials used, rounding of wetted corners) that escape control of the experimenter and are different for each campaign. As usual, more experiments are needed to elucidate the unexpected results of this one, but a clear progress in the overall experiment planning is evident. (2016) |
Materia
| Ingeniería; Física |
Palabra clave
| Spacelab
Microgravity
Experiment
Liquid bridge
Capillarity
Fluid mechanics |
Publicación relacionada
| I. Martínez, J.M. Perales, Experimental analysis of the breakage of a liquid bridge under microgravity conditions, Advances in Space Research, Volume 48, Issue 3, 3 August 2011, Pages 465-471, ISSN 0273-1177, http://dx.doi.org/10.1016/j.asr.2011.03.012. url: 9517 http://oa.upm.es/9517/
I. Martínez, J. Meseguer, J.M. Perales, Wobbling of a liquid column between unequal discs, Advances in Space Research, Volume 36, Issue 1, 2005, Pages 26-35, ISSN 0273-1177, http://dx.doi.org/10.1016/j.asr.2005.03.155 url: 5001 http://oa.upm.es/5001/
Martínez Herranz, Isidoro; Meseguer Ruiz, José y Perales Perales, José Manuel (1991). Stability of Long Liquid Columns. En: "Research Program of the German Spacelab Mission D-2". Wissenchaftliche Projektführung Spacelabmission D-2, Colonia, Alemania, pp. 221-222 url: 4975 http://oa.upm.es/4975/
Martínez Herranz, Isidoro; Perales Perales, José Manuel y Meseguer Ruiz, José (1995). Stability of Long Liquid Columns. En: "Symposium on Scientific Results of the German Spacelab Mission D-2", 14/03/1994-16/03/1994, Norderney, Germany. ISBN 978-3-89100-025-1. url: 4990 http://oa.upm.es/4990 |
Idioma
| Inglés |
Fecha de producción
| 1993 |
Lugar de producción
| Columbia, STS-55, Spacelab D2, from Oberfaffenhofen |
Colaborador
| Institución anfitriona : National Aeronautics and Space Administration (NASA)
Miembro del proyecto : Gerhard Thiele
Agencia de financiación : European Space Agency (ESA) |
Depositante
| Admin, Dataverse |
Fecha de depósito
| 2016-11-24 |
Material relacionado
| Erasmus Experiment Archive EXPERIMENT RECORD N° 7499 http://eea.spaceflight.esa.int/portal/exp/?id=7499 |